BIOTOOL代理 Poly FlAG多肽
BIOTOOL代理 Poly FlAG多肽
Appearance (Color) | White |
---|---|
Appearance (Form) | Powder |
Form | Lyophilized Powder |
Purity by HPLC-MS | 95.33 % (the latest lot) Poly FLAG Peptide lyophilized powder |
Concentration | (Recommended working concentration is 100-400 μg/mL for elute FLAG fusion proteins from the Biotool Anti-DYKDDDDK (FLAG) affinity gel. |
Shipped in | Blue ice |
Storage Temperature | 2-8°C |
For use in competitive elution of DYKDDDDK (FLAG) fusion proteins from the ANTI-FLAGmonoclonal antibody in solution or bound to agarose on the Biotool Anti-DYKDDDDK (FLAG) affinity gel.
1. Read the User Manual carefully before the first use;
2. Avoid freezing, drying and high-speed centrifugation during use and storage of beads;
3. This product is for R&D use only, not for drug, household, or other uses. Please consult the Material Safety Data Sheet for information regarding hazards and safe handling practices.
Peptide Elution of DYKDDDDK(FLAG) Fusion Protein from Biotool Anti-DYKDDDDK(FLAG) affinity gel
1. Thoroughly suspend the Anti-Flag Affinity Gel in the vial, for a uniform suspension of the resin. Quickly transfer 10μl of the gel suspension (about 5μl of packed gel volume) to a fresh tube.
2. Add 0.6 mL TBS. Thoroughly suspend the Anti-Flag Affinity Gel by pipetting. Centrifuge the resin at 5000 rpm for 30 secondsand carefully remove the supernatant. Be sure to remove all of the wash buffer without discarding the resin. Repeat 3-4 times.
3. Add 500 μL of cell periplasmic extracts to the washed resin.
4. Gently agitate samples for 2 hours at 4°C.
5. Centrifuge the resin for 30 seconds at 5000 rpm. Transfer the supernatants to a fresh tube.
6. Wash the resin with 0.5mL TBS until the OD280 of the supernatant reads<0.05.
7. Elution of DYKDDDDK (FLAG) Fusion Protein by Competition with Poly DYKDDDDK (FLAG) Peptide. Elute the bound DYKDDDDK(FLAG) Fusion Proteinby competitive elution with five one-column volume aliquots of a solution containing 100-400 ug/mL Poly DYKDDDDK(FLAG) Peptide in TBS.
8. Recycling the Biotool Anti-DYKDDDDK(FLAG) affinity gel
Poly DYKDDDDK(FLAG) Peptidemay not elute all of the DYKDDDDK(FLAG) Fusion Protein bound to Biotool Anti-DYKDDDDK(FLAG) affinity gel. It is recommended the Biotool Anti-DYKDDDDK(FLAG) Affinity gel be regenerated immediay after use by washing with three 5 mL aliquots of 0.1 M glycine HCl, pH 3.5. The gel should be immediay re-equilibrated in TBS until the effluent is at neutral pH.
Note: Do not leave the Biotool Anti-DYKDDDDK(FLAG) Affinity gel in glycine HCl for longer than 20 minutes.
9. Storing the Biotool Anti-DYKDDDDK(FLAG) Affinity gel
Wash the Biotool Anti-DYKDDDDK(FLAG) Affinity gel three times with 5 mL of 50% glycerol with 10mM sodium phosphate, 150 mM sodium chloride, pH 7.4, containing 0.02% (w/v) sodium azide. then add another 5 mL of 50% glycerol with 10 mM sodium phosphate, 150 mM sodium chloride, pH 7.4, containing 0.02% (w/v) sodium azideand store at -20°C without draining.
Store the product at 2-8°C.
Poly FLAG Peptide lyophilized powder
贬础多肽
肠-惭测肠多肽
痴5多肽
础苍迟颈-顿驰碍顿顿顿顿碍(贵濒补驳)亲和凝胶
础苍迟颈-贬础亲和凝胶
础苍迟颈-惭测肠亲和凝胶
础苍迟颈-痴5亲和凝胶
抑制剂颁辞肠办迟补颈濒蝉
蛋白纯化和免疫沉淀的磁珠系列
Graphene Oxide
BIOTOOL代理 Poly FlAG多肽
订购信息:
B23111 4mg
B23112 25mg